Description
Cosel LFA150F-24-CR2 (also known as LFA150F24CR2) is an industrial-grade 151.2W single-output open-frame AC-DC power supply from the Cosel LFA150F series, engineered for high-density OEM equipment requiring factory-applied environmental hardening and standby energy control. In Cosel nomenclature, the -C suffix denotes double-sided conformal coating on the printed circuit board to resist moisture and conductive dust, while the -R2 suffix adds an isolated remote ON/OFF control interface paired with reduced standby power consumption when the output is inhibited. Operating across a universal 85–264 VAC (120–370 VDC) input with active Power Factor Correction (PFC), it delivers a regulated 24 VDC output at 6.3 A (adjustable from 21.6 to 26.4 VDC) with up to 90% conversion efficiency, 150 mV max load regulation, and low 150 mVp-p max ripple and noise.
Constructed in an ultra-low-profile 1U-compatible open-frame footprint measuring 75 mm × 27 mm × 160 mm (2.95 in × 1.06 in × 6.30 in) and weighing 320 g (11.29 oz), the unit integrates industry-standard JST VH-series input/output headers alongside a dedicated JST XH-series CN4 remote control connector. Internal protection circuits include overcurrent protection (OCP > 105% with automatic hiccup recovery) and overvoltage protection (OVP at 27.6–33.6 VDC with latch-off shutdown). The supply enforces 3,000 VAC input-to-output reinforced galvanic isolation, operates across an ambient temperature window of -10 °C to +70 °C (+14 °F to +158 °F) with full convection-cooled load up to +50 °C (+122 °F), and holds UL 62368-1, EN 62368-1, and EN 55011/EN 55032 Class B compliance.
Key Features
- Regulated 24VDC 6.3A Output with Potentiometer Trim: Delivers 151.2W continuous output power (24VDC at 6.3A) with onboard potentiometer adjustment from 21.6VDC to 26.4VDC, ±96mV line regulation, and ±150mV load regulation.
- Factory -C & -R2 Option Configuration: Combines factory-applied PCB conformal coating (-C) against humidity and airborne contaminants with isolated remote ON/OFF control and ultra-low standby power consumption (-R2).
- Universal Input with Active Harmonic PFC: Accepts 85–264VAC (47–63Hz) or 120–370VDC input while maintaining power factor of 0.98 at 100VAC and 0.93 at 200VAC in full compliance with EN 61000-3-2.
- High 90% Efficiency & Low Dual-Stage Inrush: Achieves 87% typical efficiency at 100VAC and 90% at 200VAC with an internal dual-stage inrush limiting circuit capping primary cold-start surge to 15A/30A.
- Compact 27mm Low-Profile 1U Footprint: Measures 75mm (W) × 27mm (H) × 160mm (D) (2.95in × 1.06in × 6.30in) and weighs 320g max, fitting compact 1U rack chassis and embedded industrial enclosures.
- Comprehensive OCP & Latching OVP Protection: Features overcurrent protection above 105% rated load with intermittent hiccup auto-recovery and overvoltage protection between 27.6VDC and 33.6VDC with safety latch-off reset.
- 3,000VAC Galvanic Isolation & Safety Approvals: Provides 3,000VAC input-to-output, 2,000VAC input-to-FG, and 500VAC output-to-FG dielectric isolation, certified to UL 62368-1, C-UL, EN 62368-1, and EN 50178 standards.
Technical Specifications
| Manufacturer | Cosel |
|---|---|
| Manufacturer Part Number (MPN) | LFA150F-24-CR2 |
| Alternate Part Number | LFA150F24CR2 |
| Compatible Equipment / Series | Cosel LFA150F Optional Accessory Harnesses (H-IN-12, H-OU-19, H-RC-1) & Industrial 24VDC Embedded Systems |
| Product Series | LFA Series (LFA150F) |
| Product Category | Open Frame PSUs |
| Component Type | Open-Frame AC-DC Switching Power Supply |
| Circuit Topology | Active PFC Boost Pre-Regulator + Resonant LLC / Flyback PWM Switching Stage |
| Nominal Output Voltage | 24 VDC |
| Output Voltage Adjustment Range | 21.6 to 26.4 VDC (±10% via onboard potentiometer) |
| Rated Output Current | 6.3 A |
| Output Current Range | 0 to 6.3 A (zero minimum load required) |
| Rated Output Power | 151.2 W |
| Number of Outputs | 1 Output (Single Channel) |
| Output Ripple & Noise (Max.) | 150 mVp-p max. (0 °C to +50 °C) / 180 mVp-p max. (-10 °C to 0 °C) at 20 MHz bandwidth |
| Line Regulation | 96 mV max. (across 85–264 VAC input) |
| Load Regulation | 150 mV max. (0% to 100% load) |
| Setup Time (at 115 VAC) | 500 ms max. (at 100 / 115 VAC full load) |
| Setup Time (at 230 VAC) | 350 ms max. (at 200 / 230 VAC full load) |
| Rise Time | 50 ms max. (at 100–230 VAC full load) |
| Hold-Up Time (at 115 VAC) | 20 ms min. (at 100 / 115 VAC full load) |
| Hold-Up Time (at 230 VAC) | 20 ms min. (at 200 / 230 VAC full load) |
| AC Input Voltage Range | 85 to 264 VAC (100–240 VAC nominal) |
| DC Input Voltage Range | 120 to 370 VDC |
| Input Frequency Range | 47 to 63 Hz (50 / 60 Hz nominal) |
| Efficiency (at 115 VAC) | 87.0% typ. (at 100 / 115 VAC full load) |
| Efficiency (at 230 VAC) | 90.0% typ. (at 200 / 230 VAC full load) |
| AC Input Current (at 115 VAC) | 1.9 A typ. (at 100 VAC full load) |
| AC Input Current (at 230 VAC) | 1.0 A typ. (at 200 VAC full load) |
| Inrush Current (Cold Start at 115 VAC) | 15 A typ. primary inrush / 40 A secondary Thyristor turn-on (at 100 VAC, 25 °C) |
| Inrush Current (Cold Start at 230 VAC) | 30 A typ. primary inrush / 40 A secondary Thyristor turn-on (at 200 VAC, 25 °C) |
| Power Factor (PF at 115 VAC) | 0.98 typ. (at 100 / 115 VAC full load) |
| Power Factor (PF at 230 VAC) | 0.93 typ. (at 200 / 230 VAC full load) |
| Power Factor Correction (PFC) | Active PFC (EN 61000-3-2 Class A Compliant) |
| No-Load Power Consumption | < 0.5 W typ. with Remote ON/OFF inhibited (-R2 option at 100–240 VAC) |
| Mounting Style | Chassis / Standoff PCB Mount (Open Frame via 4× Ø3.5 mm mounting holes) |
| Cooling Method | Free Air Convection (or Forced Air Cooling for extended high-temperature operation) |
| Package / Footprint Standard | 1U Low-Profile Open Frame PCB (75 × 160 mm footprint) |
| Overall Width (W) | 75.0 mm (2.95 in) |
| Overall Height (H) | 27.0 mm (1.06 in) |
| Overall Depth (D) | 160.0 mm (6.30 in) |
| Dimensional Tolerance | ±1.0 mm (±0.04 in) max. |
| Mounting Hole Pitch | 65.0 mm × 150.0 mm (2.56 in × 5.91 in), 4× Ø3.5 mm holes |
| Net Weight | 320 g max. (0.71 lbs / 11.29 oz) |
| Termination / Connector Style | Board-Mount Nylon Pin Headers (JST VH Series for Power / JST XH Series for Control) |
| Input Terminal Pinout | CN1 (JST B3P5-VH-B, mates with VHR-5N): Pin 1 = AC(L), Pin 3 = AC(N), Pin 5 = FG (Pins 2 & 4 removed) |
| Output & Signal Terminal Pinout | CN2 / CN3 (JST B6P-VH-B, mates with VHR-6N): Pins 1–3 = -V (DC Return), Pins 4–6 = +V (+24 VDC); CN4 (JST B2B-XH-A, mates with XHP-2): Pin 1 = RC (+), Pin 2 = RCG (-) |
| Control & Monitoring Signals | Remote ON/OFF Control (-R2 Option via CN4, isolated phototransistor input: 4.5–12.5 VDC ON, 0–0.5 VDC or Open OFF; built-in auxiliary source unavailable—requires external 5–12V signal) |
| Enclosure / Potting Material | Open-Frame FR-4 Double-Sided Conformal Coated PCB (-C Option) |
| Overload Protection (OLP) Threshold | > 105% of rated output current (> 6.62 A) |
| Overload Protection (OLP) Mode | Hiccup Mode (Intermittent operation with automatic recovery upon fault removal) |
| Overvoltage Protection (OVP) Threshold | 27.6 to 33.6 VDC (115% to 140% of nominal output voltage) |
| Overvoltage Protection (OVP) Mode | Latch-Off Shutdown (Recycle AC input power for at least 3 minutes or toggle Remote ON/OFF to reset) |
| Short Circuit Protection (SCP) | Continuous Short-Circuit Protected via Hiccup Current Limiting with Auto-Recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3,000 VAC for 1 minute (20 mA cutoff) |
| Withstand Isolation Voltage (I/P to FG / Case) | 2,000 VAC for 1 minute (20 mA cutoff) |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VAC for 1 minute (100 mA cutoff) |
| Isolation Resistance (at 500 VDC) | ≥ 100 MΩ (Input-to-Output, Input-to-FG, Output-to-FG at 25 °C, 70% RH) |
| Earth Leakage Current | 0.40 mA max. (at 100 VAC, 60 Hz) / 0.75 mA max. (at 240 VAC, 60 Hz) |
| Operating Ambient Temperature Range | -10 °C to +70 °C (+14 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) under horizontal convection cooling; +60 °C (+140 °F) with ≥ 1.2 m/s forced air |
| High-Temperature Derating Rate | Linear derating at 2.5% per °C from +50 °C to +70 °C (50% max load at +70 °C under horizontal convection) |
| Low-Line Input Derating | Derate output load linearly from 100% at 90 VAC to 80% at 85 VAC input |
| Storage Temperature Range | -20 °C to +75 °C (-4 °F to +167 °F) |
| Operating Relative Humidity | 20% to 90% RH (non-condensing) |
| Storage Relative Humidity | 20% to 90% RH (non-condensing) |
| Temperature Coefficient | 0.02% / °C max. (0 °C to +50 °C) |
| Vibration Resistance | 10–55 Hz, 19.6 m/s² (2G) constant sweep for 1 min cycle, 1 hour each along X, Y, and Z axes |
| Safety Approvals (UL / North America) | UL 62368-1, C-UL (CSA C22.2 No. 62368-1) |
| Safety Approvals (IEC / EN / TÜV) | EN 62368-1, EN 50178 (OV II, PD 2), CE Marked, UKCA |
| Safety Approvals (Regional / Global) | Complies with DEN-AN (Japan Electrical Appliance and Material Safety Law) |
| EMC Conducted & Radiated Emissions | FCC Part 15 Class B, VCCI-B, CISPR 11 Class B, CISPR 32 Class B, EN 55011 Class B, EN 55032 Class B |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 (Harmonic Current Emissions Class A), EN 61000-3-3 (Voltage Fluctuations & Flicker) |
| EMC Immunity Standards | EN 55024 / EN 61000-6-2 (EN 61000-4-2 ESD, EN 61000-4-3 Radiated RF, EN 61000-4-4 EFT/Burst, EN 61000-4-5 Surge, EN 61000-4-6 Conducted RF, EN 61000-4-8 Power Frequency Magnetic Field, EN 61000-4-11 Voltage Dips & Interruptions) |
| MTBF (MIL-HDBK-217F) | > 180,000 Hours (calculated at 25 °C ambient, full rated load) |
| Environmental Compliance | RoHS Compliant, REACH Compliant, Lead-Free Manufacturing |
Industrial Applications & Compatible Systems
Engineered with factory-applied conformal coating and isolated remote inhibit control, the Cosel LFA150F-24-CR2 delivers reliable 24VDC power across space-constrained and environmentally demanding industrial systems:
- Semiconductor Wafer Fab & Cleanroom Metrology Equipment: Powers 24VDC precision stepper axes, vacuum valves, and optical sensors inside compact 1U sub-racks while conserving standby power via the CN4 remote ON/OFF interface.
- Factory Automation, Packaging & SMT Assembly Machinery: Supplies regulated 24VDC to PLCs, pneumatic solenoid manifolds, and industrial vision cameras exposed to high humidity and airborne dust thanks to its -C conformal PCB coating.
- Automated Test Equipment (ATE) & Laboratory Instrumentation: Provides low-ripple (< 150 mVp-p), EN 55011/55032 Class B low-EMI power for data acquisition chassis, benchtop analyzers, and programmable signal generators.
- Outdoor Kiosks, Ticketing Terminals & Telecom Access Nodes: Fits tight enclosure cavities requiring wide 85–264VAC input resilience, high 90% efficiency, and low standby consumption during off-peak sleep cycles.
Installation, Thermal Management & MRO Guidelines
Follow these critical mechanical mounting, wiring, and thermal design practices to maximize service life and preserve Class B EMC performance:
- Chassis Standoff Grounding & Insulation Clearance: Mount the open-frame PCB on 8 mm minimum metal or insulated standoffs using the four Ø3.5 mm corner holes, ensuring the FG mounting pad next to CN1 is bonded to the equipment protective earth for optimal EMI suppression and 5 mm clearance is maintained around high-voltage primary components.
- Convection Orientation & High-Temperature Derating: Under natural convection in standard horizontal mounting, operate at 100% load (6.3 A) up to +50 °C (+122 °F) and derate linearly at 2.5% per °C up to +70 °C; if mounted vertically, apply derating starting from +40 °C (+104 °F) or provide ≥ 1.2 m/s forced airflow across the main transformer and heatsink.
- Remote ON/OFF (-R2) Wiring & Connector Mating: Use genuine JST VHR-5N (input), VHR-6N (output), and XHP-2 (CN4 remote control) housings with twisted-pair wiring for CN4; apply 4.5–12.5 VDC between RC (Pin 1) and RC(G) (Pin 2) to enable the output, or leave open/0–0.5 VDC to place the unit into low-power standby mode.