SDS150PS15B XP Power 150W 15VDC U-Channel Power Supply

$166.87

XP Power SDS150PS15B 150W 15VDC 10A U-channel AC-DC power supply, 90-264VAC/120-370VDC input, featuring 88% efficiency, active PFC, and UL/EN 60950-1 approvals.

SKU: SDS150PS15B Category: Brand:

Description

XP Power SDS150PS15B is an industrial-grade 150W single-output AC-DC power supply from the SDS150 series, where the “PS15” nomenclature designates a single +15 VDC output rail and the “B” suffix specifies a rugged U-channel aluminum chassis enclosure. Engineered with an active power factor correction (PFC >0.9, 34 kHz minimum) front end and a 55 kHz pulse-width modulated (PWM) switching stage, the unit operates seamlessly across a universal 90–264 VAC (47–63 Hz) or 120–370 VDC input range. It delivers a continuous 15 VDC at 0 to 10.00 A (150 W rated power) with 88% typical efficiency and a high power density of 6.50 W/in³. Output stability is strictly maintained with ±1% initial set accuracy, ±5% onboard potentiometer trim (14.25–15.75 VDC), 0.5% typical line regulation, 3.0% typical load regulation, and low output ripple and noise of 1% pk-pk typical (150 mVpp at 20 MHz bandwidth).

Housed in a compact 3 × 5 inch class U-channel frame measuring 81.5 × 41.2 × 127.0 mm (3.21 × 1.62 × 5.00 in) and weighing 580 g (1.27 lbs), the supply utilizes 3.96 mm pitch Molex headers for fast harness termination (P1 AC input and 13-pin P2 DC output). Comprehensive fault protection includes 112–132% latch-off overvoltage protection (OVP), 110–150% auto-recovery primary power-limit overload protection (OLP), hiccup-mode short-circuit protection (SCP), and an internal T3.15 A / 250 VAC line fuse. The architecture provides 3000 VAC input-to-output and 1500 VAC input-to-ground galvanic isolation alongside full convection cooling from 0 °C to +50 °C at 100% load (derating linearly to 50% load at +70 °C). Certified to UL/CSA/EN 60950-1 and EN 55022 Level B conducted and radiated EMI standards, it delivers a proven MTBF exceeding 130,000 hours.

Key Features

  • High-Efficiency 15VDC Output Delivery: Supplies a tightly regulated 15 VDC rail up to 10.00 A (150 W continuous) with zero minimum load requirement, ±1% initial accuracy, and ±5% onboard potentiometer voltage trim.
  • Universal AC/DC Input & Active PFC: Operates across 90 to 264 VAC (47–63 Hz) or 120 to 370 VDC with active power factor correction (>0.9 PF) and 88% typical conversion efficiency.
  • Compact U-Channel Convection Package: Built in an 81.5 × 41.2 × 127.0 mm (3.21 × 1.62 × 5.00 in) U-channel aluminum chassis achieving 6.50 W/in³ power density without cooling fans.
  • Low Ripple & Fast Transient Recovery: Limits output ripple and noise to 1% pk-pk typical (150 mVpp at 20 MHz) and recovers within 1% in 500 µs during 50% step load changes.
  • Comprehensive Multi-Stage Protection Suite: Integrates 112–132% recycle-to-reset overvoltage protection, 110–150% auto-recovery overload protection, continuous hiccup-mode short-circuit protection, and an internal T3.15A/250V input fuse.
  • Reinforced 3000 VAC Galvanic Isolation: Provides 3000 VAC input-to-output, 1500 VAC input-to-ground, and 500 VDC output-to-ground isolation withstand voltages with 50 MΩ minimum isolation resistance.
  • Wide Thermal Operating Envelope: Delivers 100% rated 150 W output via natural convection from 0 °C to +50 °C, derating linearly at 2.5%/°C to 50% load at +70 °C.
  • Class B EMI & Safety Approvals: Certified to UL 60950-1, CSA 60950-1 (cUL), and EN 60950-1 safety standards while meeting EN 55022 Level B conducted and radiated emissions without external filtering.

Technical Specifications

Manufacturer XP Power
Manufacturer Part Number (MPN) SDS150PS15B
Compatible Equipment / Series SDS120/SDS150 CON KIT (Mating Connector Kit), SDS150 LOOM (Cable Harness), SDS150 COVER (Optional Top Cover Kit)
Product Series SDS150 Series (SDS 120-180W Family)
Product Category Chassis Power Supplies
Component Type U-Channel Enclosed Chassis-Mount AC-DC Switching Power Supply
Circuit Topology Switched-Mode Power Supply (SMPS) with Active PFC (34 kHz min) and PWM Converter (55 kHz typ)
Nominal Output Voltage 15 VDC
Output Voltage Adjustment Range 14.25 to 15.75 VDC (±5% via onboard potentiometer)
Rated Output Current 10.00 A
Output Current Range 0 to 10.00 A (No minimum load required)
Rated Output Power 150 W
Number of Outputs 1 (Single Output)
Output Ripple & Noise (Max.) 1% pk-pk typical (150 mV pk-pk at 20 MHz bandwidth)
Output Voltage Tolerance ±1% initial set accuracy; ±5% total regulation (includes line and load regulation)
Line Regulation ±0.5% typical
Load Regulation ±3.0% typical
Transient Recovery Time & Deviation 4% max deviation, recovery to within 1% in 500 µs for a 50% load change
Setup Time 2000 ms max (2 s max start-up delay)
Rise Time 2 ms typical (start-up rise time)
Hold-Up Time (at 115 VAC) 16 ms min (at 110 VAC, full load)
AC Input Voltage Range 90 to 264 VAC
DC Input Voltage Range 120 to 370 VDC
Input Frequency Range 47 to 63 Hz
Efficiency 88% typical
AC Input Current (at 115 VAC) 2.0 A max
AC Input Current (at 230 VAC) 0.8 A max
Inrush Current (Cold Start at 115 VAC) 54 A max
Inrush Current (Cold Start at 230 VAC) 63 A max
Power Factor (PF at 115 VAC) >0.9
Power Factor (PF at 230 VAC) >0.9
Power Factor Correction (PFC) Active PFC (EN 61000-3-2 Class A compliant)
Switching Frequency PFC: 34 kHz minimum; PWM: 55 kHz typical
Mounting Style Chassis Mount (U-Channel with 4 × bottom M3×P0.5 and 5 × side M3×P0.5 tapped mounting holes; max screw penetration 3.5 mm / 0.14 in)
Cooling Method Natural Free Air Convection (Convection-Cooled)
Package / Footprint Standard 3 × 5 Inch Industry-Standard U-Channel Footprint (6.50 W/in³ power density)
Overall Width (W) 81.5 mm (3.21 in)
Overall Height (H) 41.2 mm (1.62 in)
Overall Depth (D) 127.0 mm (5.00 in)
Dimensional Tolerance ±0.5 mm (±0.02 in)
Mounting Hole Pitch Bottom: 65.3 × 114.3 mm (2.57 × 4.50 in); Side: 99.0 mm / 101.6 mm / 114.3 mm (3.90 in / 4.00 in / 4.50 in) centers
Net Weight 580 g (1.27 lbs) approx.
Termination / Connector Style 3.96 mm Pitch Friction-Lock Header Pins (P1 mates with Molex 09-50-3051 housing & 2478 crimp terminals; P2 mates with Molex 09-50-3131 housing & 2478 crimp terminals)
Input Terminal Pinout Connector P1 (3-Position, 3.96 mm Pitch): Pin 1 = Line (L), Center Removed, Pin 3 = Neutral (N), Pin 5 = Ground (G); Internal T3.15 A / 250 VAC fuse in line
Output & Signal Terminal Pinout Connector P2 (13-Pin, 3.96 mm Pitch): Pins 1–6 = +V1 (+15 VDC), Pins 7–12 = Return (0V Common), Pin 13 = N/C on standard model (Power Fail Detect on -P option)
Control & Monitoring Signals Pin 13 Not Connected (N/C) on standard SDS150PS15B; TTL Active-Low Power Fail Detect (PFD, +5V normal, <0.4V fault, 16 ms warning) available on -P suffix variant
Enclosure / Potting Material Stamped Aluminum U-Channel Chassis
Overload Protection (OLP) Threshold 110% to 150% of rated output power (primary power limit)
Overload Protection (OLP) Mode Constant power limiting with automatic recovery upon fault removal
Overvoltage Protection (OVP) Threshold 112% to 132% of nominal V1 output voltage (16.8 to 19.8 VDC)
Overvoltage Protection (OVP) Mode Latching shutdown (recycle AC input power to reset)
Short Circuit Protection (SCP) Trip and restart (hiccup mode) with automatic recovery
Withstand Isolation Voltage (I/P to O/P) 3000 VAC
Withstand Isolation Voltage (I/P to FG / Case) 1500 VAC
Withstand Isolation Voltage (O/P to FG / Case) 500 VDC
Isolation Resistance (at 500 VDC) 50 MΩ minimum
Earth Leakage Current 0.40 mA at 115 VAC / 0.75 mA at 230 VAC
Operating Ambient Temperature Range 0 °C to +70 °C (+32 °F to +158 °F)
Full-Load Operating Temperature Limit +50 °C (+122 °F) at 100% load (150 W) under natural convection
High-Temperature Derating Rate Derate linearly at 2.5% per °C from 100% load (150 W) at +50 °C to 50% load (75 W) at +70 °C
Storage Temperature Range -40 °C to +85 °C (-40 °F to +185 °F)
Operating Relative Humidity 5% to 95% RH, non-condensing
Temperature Coefficient ±0.04% / °C
Safety Approvals (UL / North America) UL 60950-1, CSA C22.2 No. 60950-1 per cUL
Safety Approvals (IEC / EN / TÜV) EN 60950-1, CE Marked
EMC Conducted & Radiated Emissions EN 55022 Level B Conducted and Radiated
EMC Harmonic & Flicker Compliance EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker)
EMC Immunity Standards EN 61000-4-2 (ESD Level 2 Contact / Level 3 Air, Criteria A), EN 61000-4-3 (Radiated Level 2, Criteria A), EN 61000-4-4 (EFT/Burst Level 2, Criteria A), EN 61000-4-5 (Surge Installation Class 3, Criteria A), EN 61000-4-6 (Conducted Level 2, Criteria A), EN 61000-4-8 (Magnetic Field 1 A/m, Criteria A), EN 61000-4-11 (Voltage Dips & Interruptions: 30% 10 ms Criteria A, 60% 100 ms Criteria B, >95% 5000 ms Criteria B)
MTBF (MIL-HDBK-217F) >130,000 hours at +25 °C, Ground Benign (GB)
Environmental Compliance RoHS Compliant

Industrial Applications & Compatible Systems

XP Power SDS150PS15B is engineered for space-constrained industrial, instrumentation, and OEM electronic enclosures requiring a fanless, tightly regulated 15 VDC power architecture:

  • Analog & Mixed-Signal Test Instrumentation: Powers precision operational amplifiers, data acquisition (DAQ) front ends, transducer excitation bridges, and laboratory measurement racks requiring low 1% pk-pk ripple and noise.
  • Factory Automation & Process Control Panels: Supplies continuous 15 VDC up to 10 A for programmable automation controllers, pneumatic proportional valve manifolds, and industrial sensor networks.
  • Broadcast, Audio & Telecom Infrastructure: Integrates directly into 2U/3U rackmount chassis and RF signal distribution equipment benefiting from EN 55022 Class B EMI performance and active power factor correction.
  • Automated Kiosks & Point-of-Sale Terminals: Fits inside compact enclosure footprints where convection-cooled U-channel conduction prevents fan maintenance and acoustic noise.

Installation, Thermal Management & MRO Guidelines

Proper mechanical mounting, harness termination, and thermal derating are essential to achieve full 130,000-hour service life in industrial MRO deployments:

  • M3 Mounting Screw Penetration Limit: Secure the U-channel chassis via the bottom (65.3 × 114.3 mm pitch) or side M3×0.5 tapped holes while strictly limiting screw penetration depth to 3.5 mm (0.14 in) maximum to maintain creepage distances and prevent internal PCB damage.
  • Current Sharing Across Multi-Pin Molex Headers: Mate P1 with Molex 09-50-3051 and P2 with Molex 09-50-3131 housings using Molex 2478 crimp terminals (or order the SDS120/SDS150 CON KIT / SDS150 LOOM); wire all six +V1 pins (Pins 1–6) and all six Return pins (Pins 7–12) in parallel to distribute the 10 A load evenly across the 3.96 mm pitch contacts.
  • Convection Clearance & Thermal Derating: Allow unobstructed airflow around the U-channel frame for full 150 W operation up to +50 °C, and apply a strict linear derating of 2.5 W/°C above +50 °C (maximum 75 W / 5.0 A at +70 °C).
  • Upstream Breaker Sizing for Cold-Start Inrush: Account for the 54 A (115 VAC) / 63 A (230 VAC) cold-start inrush pulse when selecting upstream Type C or Type D miniature circuit breakers (MCBs) to avoid nuisance tripping during power-up.