Description
XP Power SDS150PS15B is an industrial-grade 150W single-output AC-DC power supply from the SDS150 series, where the “PS15” nomenclature designates a single +15 VDC output rail and the “B” suffix specifies a rugged U-channel aluminum chassis enclosure. Engineered with an active power factor correction (PFC >0.9, 34 kHz minimum) front end and a 55 kHz pulse-width modulated (PWM) switching stage, the unit operates seamlessly across a universal 90–264 VAC (47–63 Hz) or 120–370 VDC input range. It delivers a continuous 15 VDC at 0 to 10.00 A (150 W rated power) with 88% typical efficiency and a high power density of 6.50 W/in³. Output stability is strictly maintained with ±1% initial set accuracy, ±5% onboard potentiometer trim (14.25–15.75 VDC), 0.5% typical line regulation, 3.0% typical load regulation, and low output ripple and noise of 1% pk-pk typical (150 mVpp at 20 MHz bandwidth).
Housed in a compact 3 × 5 inch class U-channel frame measuring 81.5 × 41.2 × 127.0 mm (3.21 × 1.62 × 5.00 in) and weighing 580 g (1.27 lbs), the supply utilizes 3.96 mm pitch Molex headers for fast harness termination (P1 AC input and 13-pin P2 DC output). Comprehensive fault protection includes 112–132% latch-off overvoltage protection (OVP), 110–150% auto-recovery primary power-limit overload protection (OLP), hiccup-mode short-circuit protection (SCP), and an internal T3.15 A / 250 VAC line fuse. The architecture provides 3000 VAC input-to-output and 1500 VAC input-to-ground galvanic isolation alongside full convection cooling from 0 °C to +50 °C at 100% load (derating linearly to 50% load at +70 °C). Certified to UL/CSA/EN 60950-1 and EN 55022 Level B conducted and radiated EMI standards, it delivers a proven MTBF exceeding 130,000 hours.
Key Features
- High-Efficiency 15VDC Output Delivery: Supplies a tightly regulated 15 VDC rail up to 10.00 A (150 W continuous) with zero minimum load requirement, ±1% initial accuracy, and ±5% onboard potentiometer voltage trim.
- Universal AC/DC Input & Active PFC: Operates across 90 to 264 VAC (47–63 Hz) or 120 to 370 VDC with active power factor correction (>0.9 PF) and 88% typical conversion efficiency.
- Compact U-Channel Convection Package: Built in an 81.5 × 41.2 × 127.0 mm (3.21 × 1.62 × 5.00 in) U-channel aluminum chassis achieving 6.50 W/in³ power density without cooling fans.
- Low Ripple & Fast Transient Recovery: Limits output ripple and noise to 1% pk-pk typical (150 mVpp at 20 MHz) and recovers within 1% in 500 µs during 50% step load changes.
- Comprehensive Multi-Stage Protection Suite: Integrates 112–132% recycle-to-reset overvoltage protection, 110–150% auto-recovery overload protection, continuous hiccup-mode short-circuit protection, and an internal T3.15A/250V input fuse.
- Reinforced 3000 VAC Galvanic Isolation: Provides 3000 VAC input-to-output, 1500 VAC input-to-ground, and 500 VDC output-to-ground isolation withstand voltages with 50 MΩ minimum isolation resistance.
- Wide Thermal Operating Envelope: Delivers 100% rated 150 W output via natural convection from 0 °C to +50 °C, derating linearly at 2.5%/°C to 50% load at +70 °C.
- Class B EMI & Safety Approvals: Certified to UL 60950-1, CSA 60950-1 (cUL), and EN 60950-1 safety standards while meeting EN 55022 Level B conducted and radiated emissions without external filtering.
Technical Specifications
| Manufacturer | XP Power |
|---|---|
| Manufacturer Part Number (MPN) | SDS150PS15B |
| Compatible Equipment / Series | SDS120/SDS150 CON KIT (Mating Connector Kit), SDS150 LOOM (Cable Harness), SDS150 COVER (Optional Top Cover Kit) |
| Product Series | SDS150 Series (SDS 120-180W Family) |
| Product Category | Chassis Power Supplies |
| Component Type | U-Channel Enclosed Chassis-Mount AC-DC Switching Power Supply |
| Circuit Topology | Switched-Mode Power Supply (SMPS) with Active PFC (34 kHz min) and PWM Converter (55 kHz typ) |
| Nominal Output Voltage | 15 VDC |
| Output Voltage Adjustment Range | 14.25 to 15.75 VDC (±5% via onboard potentiometer) |
| Rated Output Current | 10.00 A |
| Output Current Range | 0 to 10.00 A (No minimum load required) |
| Rated Output Power | 150 W |
| Number of Outputs | 1 (Single Output) |
| Output Ripple & Noise (Max.) | 1% pk-pk typical (150 mV pk-pk at 20 MHz bandwidth) |
| Output Voltage Tolerance | ±1% initial set accuracy; ±5% total regulation (includes line and load regulation) |
| Line Regulation | ±0.5% typical |
| Load Regulation | ±3.0% typical |
| Transient Recovery Time & Deviation | 4% max deviation, recovery to within 1% in 500 µs for a 50% load change |
| Setup Time | 2000 ms max (2 s max start-up delay) |
| Rise Time | 2 ms typical (start-up rise time) |
| Hold-Up Time (at 115 VAC) | 16 ms min (at 110 VAC, full load) |
| AC Input Voltage Range | 90 to 264 VAC |
| DC Input Voltage Range | 120 to 370 VDC |
| Input Frequency Range | 47 to 63 Hz |
| Efficiency | 88% typical |
| AC Input Current (at 115 VAC) | 2.0 A max |
| AC Input Current (at 230 VAC) | 0.8 A max |
| Inrush Current (Cold Start at 115 VAC) | 54 A max |
| Inrush Current (Cold Start at 230 VAC) | 63 A max |
| Power Factor (PF at 115 VAC) | >0.9 |
| Power Factor (PF at 230 VAC) | >0.9 |
| Power Factor Correction (PFC) | Active PFC (EN 61000-3-2 Class A compliant) |
| Switching Frequency | PFC: 34 kHz minimum; PWM: 55 kHz typical |
| Mounting Style | Chassis Mount (U-Channel with 4 × bottom M3×P0.5 and 5 × side M3×P0.5 tapped mounting holes; max screw penetration 3.5 mm / 0.14 in) |
| Cooling Method | Natural Free Air Convection (Convection-Cooled) |
| Package / Footprint Standard | 3 × 5 Inch Industry-Standard U-Channel Footprint (6.50 W/in³ power density) |
| Overall Width (W) | 81.5 mm (3.21 in) |
| Overall Height (H) | 41.2 mm (1.62 in) |
| Overall Depth (D) | 127.0 mm (5.00 in) |
| Dimensional Tolerance | ±0.5 mm (±0.02 in) |
| Mounting Hole Pitch | Bottom: 65.3 × 114.3 mm (2.57 × 4.50 in); Side: 99.0 mm / 101.6 mm / 114.3 mm (3.90 in / 4.00 in / 4.50 in) centers |
| Net Weight | 580 g (1.27 lbs) approx. |
| Termination / Connector Style | 3.96 mm Pitch Friction-Lock Header Pins (P1 mates with Molex 09-50-3051 housing & 2478 crimp terminals; P2 mates with Molex 09-50-3131 housing & 2478 crimp terminals) |
| Input Terminal Pinout | Connector P1 (3-Position, 3.96 mm Pitch): Pin 1 = Line (L), Center Removed, Pin 3 = Neutral (N), Pin 5 = Ground (G); Internal T3.15 A / 250 VAC fuse in line |
| Output & Signal Terminal Pinout | Connector P2 (13-Pin, 3.96 mm Pitch): Pins 1–6 = +V1 (+15 VDC), Pins 7–12 = Return (0V Common), Pin 13 = N/C on standard model (Power Fail Detect on -P option) |
| Control & Monitoring Signals | Pin 13 Not Connected (N/C) on standard SDS150PS15B; TTL Active-Low Power Fail Detect (PFD, +5V normal, <0.4V fault, 16 ms warning) available on -P suffix variant |
| Enclosure / Potting Material | Stamped Aluminum U-Channel Chassis |
| Overload Protection (OLP) Threshold | 110% to 150% of rated output power (primary power limit) |
| Overload Protection (OLP) Mode | Constant power limiting with automatic recovery upon fault removal |
| Overvoltage Protection (OVP) Threshold | 112% to 132% of nominal V1 output voltage (16.8 to 19.8 VDC) |
| Overvoltage Protection (OVP) Mode | Latching shutdown (recycle AC input power to reset) |
| Short Circuit Protection (SCP) | Trip and restart (hiccup mode) with automatic recovery |
| Withstand Isolation Voltage (I/P to O/P) | 3000 VAC |
| Withstand Isolation Voltage (I/P to FG / Case) | 1500 VAC |
| Withstand Isolation Voltage (O/P to FG / Case) | 500 VDC |
| Isolation Resistance (at 500 VDC) | 50 MΩ minimum |
| Earth Leakage Current | 0.40 mA at 115 VAC / 0.75 mA at 230 VAC |
| Operating Ambient Temperature Range | 0 °C to +70 °C (+32 °F to +158 °F) |
| Full-Load Operating Temperature Limit | +50 °C (+122 °F) at 100% load (150 W) under natural convection |
| High-Temperature Derating Rate | Derate linearly at 2.5% per °C from 100% load (150 W) at +50 °C to 50% load (75 W) at +70 °C |
| Storage Temperature Range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Operating Relative Humidity | 5% to 95% RH, non-condensing |
| Temperature Coefficient | ±0.04% / °C |
| Safety Approvals (UL / North America) | UL 60950-1, CSA C22.2 No. 60950-1 per cUL |
| Safety Approvals (IEC / EN / TÜV) | EN 60950-1, CE Marked |
| EMC Conducted & Radiated Emissions | EN 55022 Level B Conducted and Radiated |
| EMC Harmonic & Flicker Compliance | EN 61000-3-2 Class A (Harmonic Currents), EN 61000-3-3 (Voltage Flicker) |
| EMC Immunity Standards | EN 61000-4-2 (ESD Level 2 Contact / Level 3 Air, Criteria A), EN 61000-4-3 (Radiated Level 2, Criteria A), EN 61000-4-4 (EFT/Burst Level 2, Criteria A), EN 61000-4-5 (Surge Installation Class 3, Criteria A), EN 61000-4-6 (Conducted Level 2, Criteria A), EN 61000-4-8 (Magnetic Field 1 A/m, Criteria A), EN 61000-4-11 (Voltage Dips & Interruptions: 30% 10 ms Criteria A, 60% 100 ms Criteria B, >95% 5000 ms Criteria B) |
| MTBF (MIL-HDBK-217F) | >130,000 hours at +25 °C, Ground Benign (GB) |
| Environmental Compliance | RoHS Compliant |
Industrial Applications & Compatible Systems
XP Power SDS150PS15B is engineered for space-constrained industrial, instrumentation, and OEM electronic enclosures requiring a fanless, tightly regulated 15 VDC power architecture:
- Analog & Mixed-Signal Test Instrumentation: Powers precision operational amplifiers, data acquisition (DAQ) front ends, transducer excitation bridges, and laboratory measurement racks requiring low 1% pk-pk ripple and noise.
- Factory Automation & Process Control Panels: Supplies continuous 15 VDC up to 10 A for programmable automation controllers, pneumatic proportional valve manifolds, and industrial sensor networks.
- Broadcast, Audio & Telecom Infrastructure: Integrates directly into 2U/3U rackmount chassis and RF signal distribution equipment benefiting from EN 55022 Class B EMI performance and active power factor correction.
- Automated Kiosks & Point-of-Sale Terminals: Fits inside compact enclosure footprints where convection-cooled U-channel conduction prevents fan maintenance and acoustic noise.
Installation, Thermal Management & MRO Guidelines
Proper mechanical mounting, harness termination, and thermal derating are essential to achieve full 130,000-hour service life in industrial MRO deployments:
- M3 Mounting Screw Penetration Limit: Secure the U-channel chassis via the bottom (65.3 × 114.3 mm pitch) or side M3×0.5 tapped holes while strictly limiting screw penetration depth to 3.5 mm (0.14 in) maximum to maintain creepage distances and prevent internal PCB damage.
- Current Sharing Across Multi-Pin Molex Headers: Mate P1 with Molex 09-50-3051 and P2 with Molex 09-50-3131 housings using Molex 2478 crimp terminals (or order the SDS120/SDS150 CON KIT / SDS150 LOOM); wire all six +V1 pins (Pins 1–6) and all six Return pins (Pins 7–12) in parallel to distribute the 10 A load evenly across the 3.96 mm pitch contacts.
- Convection Clearance & Thermal Derating: Allow unobstructed airflow around the U-channel frame for full 150 W operation up to +50 °C, and apply a strict linear derating of 2.5 W/°C above +50 °C (maximum 75 W / 5.0 A at +70 °C).
- Upstream Breaker Sizing for Cold-Start Inrush: Account for the 54 A (115 VAC) / 63 A (230 VAC) cold-start inrush pulse when selecting upstream Type C or Type D miniature circuit breakers (MCBs) to avoid nuisance tripping during power-up.